7th Floor Washroom Modification Work, as per approved annexure attached
all loose parical and silver memrone remove and area clean then apply two coat of liquid black rubber mambrone with fibre net
Charges towards water proofing work at breakout area with required leveling work (Dr. Fix IT)
Chemical Waterproofing, Dry Area and Wet Area, Polymeric Waterproofing Coating, Surface Preparation including Repair and Make Good of faulty concrete cracks and honeycombing
Crack Repair, Construction Joint Treatment & Waterproofing: All visible hairline cracks on concrete roof screed more than 0.50mm and not giving hollow sound, should be cut and widen in V/U shape with mechanical cutter
Doing water proofing work with required water proofing agents and chemicals
Dr Fixit
DR.Fixit All Seal 20 Kgs
Dr Fixit PD FINE 2kg
DR FIXIT PIDICRETE URP 10 LITRE (301)
DR. FIXIT PIDICRETE URP 1KG.
DR. FIXIT PIDICRETE URP - 20KG
DR FIXIT PIDICRETE URP 5 LITRE (301)
Dr Fixit URP 5ltr
DR. FX PIDIPROOF LW+50LTR
EPDM Sheet, 16mm Thick, 9 Rolls x 20 Sqm
Epoxy Grouting, Men and Women Washroom, MYK Laticrete Epoxy SP 100 3-Component Material or Dr. Fixit Roff Epoxy 3-Component Material; Work Procedure: Cutting gaps between tiles and removing existing white grout
Hendicap washroom exsiting pee bricbat coba with sunken area.
Liquid Membrane Coating, Old Ceiling System 1, surface preparation of Kota Stone joints opened with grinder and cleaned, Starproof WF SP 600 MAKE
MD Area Washroom waterproofing
P&A 304 or Fidifix 2K Dr. Fixit Cement Coating Waterproofing with Mesh Protective Layer of Cement Mortar Floor Plaster with Cement and Sand, with 24 Hours Pond Testing of Slab and Wall
P&F Fire Stop Mortar System, Fire-rated 2 Hours, Through Penetration on Floor, Medium to Large size 4" gaps, horizontal openings in floors or slabs, tested per UL 1479/ASTM-E 814
P&F Sprayable Fire-Rated Joint Spray, Minimum 2 Hours Fire Rating, Joints (Top of Wall) between Vertical Concrete/Masonry Wall and Deck Slab
Pidicrete Urp (10 Kg)
P&L Waterproofing Treatment, Depressed WC/Kitchen Areas, 4-Course System: (i) Cement Slurry with WP Compound @ 4.4 kg/sqm IS 2645, (ii) 20mm Cement Plaster 1:3 with WP Compound, (iii) Blown/Residual Bitumen Hot-Applied @ 1.7 kg/sqm, (iv) 400 Micron PVC Sheet with 100mm Overlap Joints Bitumen-Bonded
P&L Water Proofing Treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound as per manufacturer's specification, consisting of applying: a) First layer of cement
Preparation of surface for waterproofing treatment including removing all base treatment ,mortar and cleaning the same etc.all complete .for wash room
Preparation of surface for waterproofing treatment including removing all base treatment ,mortar and cleaning the same etc. all complete .for wash room In clod all material
Preparation of surface for waterproofing treatment including removing all base treatment ,mortar and cleaning the same etc.all complete .for wash room In clud all material
Preparation of surface for waterproofing treatment including removing all base treatment ,mortar and cleaning the same etc.all complete .for wash room In clud all material.
Preparation of surface for waterproofing treatment incuding removing all base treatment mortar and cleaning the same etc. All complete for washroom in clud all material
Preparation of Surface for Waterproofing Treatment, Removing All Base Treatment Mortar and Cleaning, All Complete for Washroom Including All Material
Providing and applying Membrane type water proofing with 3 coats of brush applications over the slab surface. Cost of the water proofing shall include cleaning of the surface of all dirt and grit before the application. The brush application shall be carr
Providing & applying Dr. fixit waterproofing 18 inch depth floor sunken area
Providing & applying requisite waterproofing on floor base surface as per site condition Considered area 30 sqft
Providing, supplying, mixing and applying two coats of approved waterproofing compound, as per the directions below. Surface preparation should include cleaning the surface of all dust, oil, grease, oil or any other surface treatment agent etc. All static
Rectificaiton of wall panel in the restroom area of 5th floor, waterproofing plywood to be used and laminate colour size to be matched with existing design, rate includes removal and carting away of debris.
Roadsil 25kg
Supply and Application of Polyurea, 2 Component Rapid Setting Hybrid, applied evenly on primed surface in 1 or 2 coats as per requirement, minimum average thickness 1.5mm
Surface Preparation: Remove all existing waterproofing primer from surface; removal and re-fixing of equipment/electrical cable conduit/tray and/or other obstructions
Through Penetration Firestop, Acrylic Firestop Sealant, Floor/Wall, annular gaps up to 50mm, around non-combustible penetrants like ducts or metal pipes passing through floor slab, minimum 2 hours fire rating
TSPO Termiseal Service (Post-Conc), Commercial, Premise: Riico Ind. Area Mansarovar, 1 Year Warranty, Area Coverage 5500 Sqft
URP PIDICRETE 5KG DR FIXIT
URP PIDICRETE 5KG DR. FIXIT
wash room and pantry leakage check work
Waterproofing
Water Proofing
Water proofing 2 coats with the gap of 4 hours
Water Proofing (Floor)- Additional
Waterproofing Treatment: Surface preparation by chipping loose concrete and plaster over floor surface; fillet work along floor and wall junction by cutting groove 15mm deep x 10mm wide, removal of loose dust
WATERPROOFING WORK